Do not place articles containing liquids on top of the heater. Hand or body contact with the louvers should be avoided. Young children should be supervised at all times. GAS Gasoline LPGAS Filter should be cleaned at regular intervals. Do not allow anyone to poke articles through the louvers. SAFETY POINTS Keep flammable materials, trees, shrubs, etc., away from the flue terminal. Do not allow curtains or other flammable or combustible materials to come into contact with the heater.
Rinnai heater energysaver 431f install#
Do not install the heater in an unusually dusty area. Most aerosols contain butane gas, and can be a fire hazard if used near this heater when it is in use. Do not spray aerosols while the heater is operating. This appliance must not be used for any purpose other than heating. SAFETY POINTS Do not restrict the warm air discharge by placing articles in front of the heater. fuse Fan delay – Micro computer timer Pre-purge – Combustion fan, pre-purge timer, spark sensor Room over heat – Automatic cut off at 104☏ after 10 minutes HI LOW 38 32dB(A) Combustion Method Forced combustion Air Supply Exhaust Closed Type Radiation Method Forced convection Wall Penetration Hole Max. Safety Devices Noise Level Range TYPE AIR SUPPLY/ EXHAUST PIPE Flame failure – Flame rod Over heat – Bi-metal switch, thermal fuse, thermistor Power failure – PCB Power surge – 3 Amp. Adequate clearances for accessibility for purposes of servicing and proper operation should be provided. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. Do not use this room heater if any part has been under water. LPG containers must not be installed indoors. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE HEATER.

Rinnai heater energysaver 431f manual#
Included in Carton: Customers Operating Information IMPORTANT Before using this product, please read this manual carefully to insure proper use of product.

Refer to local gas authority for confirmation of gas type if you are in doubt. Before installing a heater, check the label for the correct gas type (see label on heater). (DO NOT INSTALL DAMAGED HEATER.) If heater is damaged, contact your supplier for advise. IMPORTANT POINTS / USAGE AND INSTALLATION MUSTS Unpack heater and check for damage. Rinnai is continually updating and improving products therefore specifications are subject to change without prior notice. Local and state codes must be adhered to prior to installation. Power Outage Safety Device: This safety device cuts off gas passage and stops operation. If fuse blows all indicator lamps will be “OFF”. Design to shut unit down in case of overcurrent. Overcurrent Prevention Device: This is a 3 amp. įEATURES OF THE RHFE-431FA ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ UNITS Clean Heating Forced Flue Type Easy Operation One-Touch Ignition Sensible Temperature Control Feature Comfortable Room Temperature Control and Display Warm Air Outlet at Floor Level (Keeps Your Feet Warm) Child Safety Lock Room Temperature Setting Memory Dirty Air Filter Indicator Lamp Energy-Saving Economy Setting Humidifier Tray Air Flow Directional Louvers Direct Vent Easily Installed Proportional Heating Variable Capacity Hush! Quiet Ope ENERGYSAVER RHFE-431FA Operation Manual Table of Contents Page FEATURES OF THE RHFE-431FA UNITS. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. WARNING IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE, REFER TO THE OWNER'S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE. ─ Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. HOME OWNER / INSTALLER FOR YOUR SAFETY THIS MANUAL MUST BE READ IN ITS ENTIRETY BEFORE OPERATING HEATER RHFE-431FAⅢ ENERGYSAVER GAS DIRECT VENT WALL FURNACE Owner’s Operation and Installation Manual WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.